検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 2 件中 1件目~2件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

3D position and radioactivity estimation of radiation source by a simple directional radiation detector combined with structure from motion

佐藤 優樹; 峯本 浩二郎*; 根本 誠*

Radiation Measurements, 142, p.106557_1 - 106557_6, 2021/03

 被引用回数:2 パーセンタイル:30.55(Nuclear Science & Technology)

It is important to visualize radioactive substances' position and distribution and estimate their radioactivity levels to reduce the exposure dose of workers in radioactive areas (such as decommissioning worksites of nuclear power stations) and improve nuclear security functions. To visualize the radioactive substance's three-dimensional (3D) location, a directional radiation detector with a cylindrical shield on a simple single-pixel gamma-ray detector was applied to the structure from motion (SfM) technology using an ordinary digital camera. Verification was performed by a system that combines SfM with a CdTe sensor probe having narrow directivity. $$^{241}$$Am radiation source's position was visualized by drawing the radiation source's image acquired by the gamma-ray detector on the work area 3D model reconstructed through SfM. Furthermore, as SfM is a simultaneous localization and mapping technology, the system measures the gamma rays while measuring the gamma-ray detector's dynamic position and posture information. The measurements can be acquired while the gamma-ray detector is freely moving in the work area. These methods visualized the radiation source's position and quantitatively estimated the radiation source's radioactivity.

論文

Development of compact Compton camera for 3D image reconstruction of radioactive contamination

佐藤 優樹; 寺阪 祐太; 小澤 慎吾*; 宮村 浩子; 冠城 雅晃; 谷藤 祐太; 川端 邦明; 鳥居 建男

Journal of Instrumentation (Internet), 12(11), p.C11007_1 - C11007_8, 2017/11

 被引用回数:19 パーセンタイル:66.74(Instruments & Instrumentation)

The Fukushima Daiichi Nuclear Power Station (FDNPS), operated by Tokyo Electric Power Company Holdings, Inc., went into meltdown after the large tsunami caused by the Great East Japan Earthquake of March 11, 2011. Very large amounts of radionuclides were released from the damaged plant. Radiation distribution measurements inside the building of FDNPS are indispensable to execute the decommission tasks in the reactor buildings. We have developed a light-weight compact Compton camera to three-dimensionally measure the distribution of radioactive contamination inside FDNPS. The total weight of the Compton camera is lower than 1.0 kg. The $$gamma$$-ray sensor of the Compton camera employs the Ce-doped GAGG scintillators coupled with a multi-pixel photon counter (MPPC: Hamamatsu Photonics K.K.,). We performed the 3D image reconstruction of the $$^{137}$$Cs-radioactive sources as shown in Fig. 1; the 3D radiation image is reconstructed using the multi-angle data measured with the Compton camera. Here, we introduce the development status of the 3D radiation imaging system consisting of the Compton camera. Moreover, we present the results of a performance evaluation test for 3D image reconstruction of radioactive contaminations in details.

2 件中 1件目~2件目を表示
  • 1